How to read the flow and pressure parameters of a micro water pump?

      管理员   2026-11-20

For micro diaphragm pumps, the most critical indicators are free flow (maximum flow at zero pressure) and shut-off pressure (maximum pressure when the outlet is blocked). These two values cannot be achieved at the same time: the higher the pressure, the lower the flow rate. For selection, always refer to the Q-P curve and check the flow rate at the operating point matching your system resistance, instead of only looking at these two extreme values.

1. How to read flow parameters

  • Free flow / open flow (L/min, mL/min, LPM) This is the maximum flow measured when the outlet is fully open with almost no backpressure. Sellers tend to highlight this value. Fittings, filters, nozzles and elbows all create resistance, so the actual flow will always be much lower. Example: A pump marked 6 L/min free flow may only deliver 2~3 L/min in practice with a filter and thin tubing installed.
  • Rated flow (priority indicator) It refers to the flow specified by the manufacturer under rated working pressure. This value is close to the real flow under your working condition. Many low-cost pumps do not list rated flow and only mark free flow, which is a common pitfall.

Unit conversion: 1 L/min = 1000 mL/min

2. How to read pressure parameters (common conversion reference)

Common units: MPa / bar / kg (kgf/cm²) / m head 0.1 MPa = 1 bar ≈ 1 kgf/cm² ≈ 10 meters water head

  • Shut-off pressure / maximum output pressure (blocked pressure) It is the highest pressure reached when the outlet is fully closed and flow = 0. Diaphragm pumps equipped with a pressure switch will stop automatically once this pressure is reached. ⚠️ There is zero flow at shut-off pressure. It cannot be used as continuous working pressure; it only represents the upper pressure limit of the pump.
  • Rated pressure Paired with rated flow. It is the recommended stable working pressure for long-term operation, delivering optimal efficiency and service life.
  • Head (H, in meters) The vertical height the pump can lift liquid. Total head = vertical lifting height + pipe friction loss + local resistance loss (elbows, reducers, valves, filter cartridges). Do not calculate only the vertical height; resistance loss often accounts for a large proportion.
  • Suction lift (m, negative pressure at inlet) For self-priming pumps only: the maximum vertical distance from the liquid surface to the pump inlet. Most centrifugal micro pumps are non-self-priming and must be submerged (submersible type). Diaphragm pumps usually have a suction lift of 2~4 m. Do not design at the full rated value; reserve a safety margin.

3. Relationship between flow and pressure (diaphragm pump, the most common micro pump type)

Inverse proportional curve rule: Pressure = 0 (open outlet) → maximum flow (free flow) Flow = 0 (blocked outlet) → maximum pressure (shut-off pressure)

Selection tip: First calculate the total backpressure of your system, then check the Q-P curve to confirm whether the remaining flow under this backpressure meets your requirement. Example: If your piping plus nozzle creates a total resistance of 0.2 MPa, check the flow value on the curve at 0.2 MPa, do not use the free flow figure.

 
     